Computer system validation principles connect the intended regulated use of a computerized system to documented evidence that its relevant functions perform as expected. The approach should be proportionate to risk, consistent with applicable requirements and maintainable through the system lifecycle.
For project-specific support, explore computer system validation consulting.
Principle 1: Define the intended use
Establish the business process, user roles, configuration, inputs, outputs and regulated records. A platform can support multiple workflows with different risks and applicable obligations. Define boundaries so the validation evidence addresses the actual use rather than a generic product description.
Principle 2: Assess applicable requirements and risk
Determine which requirements govern the regulated activity, including applicable electronic record obligations. Evaluate function failure and its consequences. Risk helps determine the assurance approach; it does not authorize ignoring binding requirements.
Principle 3: Maintain traceability
Link requirements to relevant risks, configuration, assurance activities, outcomes and deviations. Traceability enables reviewers to identify untested requirements and helps owners assess future changes. The format can vary as long as the relationships are controlled and reviewable.
Principle 4: Use relevant evidence efficiently
Review supplier evidence, configuration records and previously established assurance results. Select testing methods that address uncovered risks. Where IQ, OQ or PQ terminology is useful, define the intended evidence for each activity rather than treating document labels as proof of control.
Principle 5: Maintain the system after release
Reconcile results and obtain accountable approval of the baseline. Define operational controls, change assessment, incident handling, periodic review and record retention or retirement. Validation is an ongoing responsibility, not a one-time certificate.
Evidence and decision matrix
| Area | Evidence or action | Owner / decision |
|---|---|---|
| Intended use | Workflow, users, records and boundaries | Business owner |
| Applicability | Binding requirements and relevant guidance | QA / regulatory |
| Risk | Failure impact and assurance rationale | Validation lead |
| Traceability | Requirement-risk-evidence relationships | Validation team |
| Evidence | Results, deviations and configuration | System owner |
| Lifecycle | Approval, change, periodic review and retirement | Operational owner |
Practical example
A quality software platform may include regulated deviation approvals and a noncritical informational view. Document each use and its associated risks. The approval workflow may require specific control and failure tests, while the informational function may justify different evidence. The release conclusion should explain the basis for both.
Related reading: DQ, IQ, OQ and PQ qualification.
Regulatory references and scope
Apply regulatory requirements to their scope. Guidance and practical frameworks are not universal legal requirements.
- 21 CFR Part 11 — Electronic records and electronic signatures
- FDA Part 11: Scope and Application (guidance)
- 21 CFR 211.68 — Automatic, mechanical and electronic equipment
- ICH Q9(R1) Quality Risk Management (FDA guidance)
- FDA Computer Software Assurance for Production and Quality Management System Software (February 2026)
- European Commission EudraLex Volume 4 — Annex 11